FRO-203 RR Spo2 Pediatric Pulse Oximeter Home Use Pulse Oximeter
Product Attributes
TYPE |
Home monitoring |
Category |
Pulse oximeter |
Series |
Narigmed® FRO-203 |
Package |
1pcs/box, 60box/carton |
Display type |
Red LED |
Display parameter |
SPO2\PR\LED |
SpO2 measurement range |
35%~100% Ultra wide range |
SpO2 measurement Accuracy |
±2%(70%~100%) |
PR measurement range |
25~250bpm Ultra wide range |
PR measurement Accuracy |
The greater of ±2bpm and±2% |
Anti-motion performance |
SpO2±3% PR ±4bpm |
Low perfusion performance |
SPO2 ±2%, PR ±2bpm |
new parameter |
The new parameter shows PI \ perfusion intensity |
perfusion Index Range |
0.02%~20% |
Respiratory rate |
4rpm~70rpm |
Initial output time/Measurement time |
4s |
Automatic shutdown |
Power off after finger out 8s\Automatic shutdown in 8 seconds |
Comfortable |
Silicone cavity finger pad, can be worn comfortably for a long time |
plethysmogram |
YES |
Switch display direction |
Manual switch by default, automatic rotation can be customized |
Low battery indicator\Battery status |
YES |
Viewing historical Data |
YES |
Health aide reminder |
YES |
Adjustable irradiance |
The screen brightness is adjustable |
Typical power consumption |
<30mA |
Weights |
54g(with bag without batteries) |
Dismension |
62mm*35mm*31mm |
Product Status |
Self-developed products |
Voltage - Supply |
2*1.5V AAA Batteries |
Operating Temperature |
5°C ~ 40°C 15%~95%( humidity) 50kPa~107.4kPa |
storage environment |
-20°C ~ 55°C 15%~95%( humidity) 50kPa~107.4kPa |
Following Features
1. High-precision measurement under low perfusion. Under weak perfusion conditions with PI=0.025%, Narigmed’s blood oxygen measurement accuracy is SpO2 ±2%.
2. Anti-exercise performance, pulse rate measurement accuracy is ±2bpm under exercise conditions
3. Fully silicone-covered finger pads, comfortable and compression-free
4. Added respiratory rate (RR) quick measurement output (tip: available in CE and NMPA).
5. Display screen rotation function.
6. Health Asst (Health Status Report): There is a small eye on the screen that flashes every eight seconds with an interval of 10 to 12 seconds. When the little eyes are not blinking, press and hold the power button to enter the health analysis prompt function, which will prompt whether hypoxia or high heart rate is suspected. Please wait to notify the customer of the status.
7.The hospital can do it, with a registration certificate
Applicable groups
Parkinson's disease patients, people living in plateau areas, people with poor blood circulation, adults and children, people with dark skin, etc.