Bedside SpO2 Patient Monitoring System for neonate SpO2\PR\RR\PI
Product Attributes
TYPE |
Bedside SpO2 Patient Monitoring System \ NICU\ICU |
Category |
Bedside SpO2 Patient Monitoring System for neonate |
Series |
narigmed® BTO-100CXX |
Package |
1pcs/box, 8box/carton |
Display type |
5.0 inch LCD |
Display parameter |
SPO2\PR\PI\RR |
SpO2 measurement range |
35%~100% |
SpO2 measurement Accuracy |
±2%(70%~100%) |
PR measurement range |
30~250bpm |
PR measurement Accuracy |
The greater of ±2bpm and±2% |
Anti-motion performance |
SpO2±3% PR ±4bpm |
Low perfusion performance |
SPO2 ±2%, PR ±2bpm |
low perfusion can be supported at least |
0.025% |
Initial output time/Measurement time |
4s |
new parameter |
respiratory rate(RR) |
0.02%~20% |
|
Respiratory rate |
4rpm~70rpm |
Initial output time/Measurement time |
4S |
Typical power consumption |
<40mA |
Alarm management system |
YES |
Probe drop detection |
YES |
historical trend data |
YES |
One click to turn off the alarm |
YES |
Patient type management |
YES |
Suitable People |
Suitable for more than 1Kg neonate OR adult |
Weights |
803g(with bag ) |
Dismension |
26.5cm*16.8cm*9.1cm |
Product Status |
Self-developed products |
Voltage - Supply |
Type-C 5V or Lithium battery power supply |
Operating Temperature |
5°C ~ 40°C 15%~95%( humidity) 50kPa~107.4kPa |
storage environment |
-20°C ~ 55°C 15%~95%( humidity) 50kPa~107.4kPa
|
Following Features
1\ High precision measurement at low perfusion
2\ anti-motion
3\ Fully silicone-covered finger pads, comfortable and non-compressive
4\ New parameter: Respiratory Rate(RR) (Tips: available at CE and NMPA).( reathing rate is also known as your breathing rate. It indicates the number of breaths you take per minute. A normal adult breathes approximately 12-20 times per minute.)
5\Comprehensive functions: It can measure key physiological indicators such as blood oxygen saturation (Spo2), pulse rate (PR), respiratory rate (RR) and perfusion index parameters (PI) of newborns.
6\Wide heart rate range: supports measurement of an ultra-wide heart rate range and adapts to the changing characteristics of rapid heart rate fluctuations of newborns.
7\Universal use for hands and feet: Whether it is hands or feet, it can be measured accurately, solving the problem of newborns with poor peripheral circulation and weak signals.
8\Special probe and algorithm optimization: Through the specially designed probe and matching software algorithm, even in the case of poor blood circulation and insufficient perfusion in newborns, signals can be effectively captured and processed to ensure that various items can be clearly displayed. Measured value.
In summary, the Narigmed brand neonatal bedside oximeter can provide accurate and reliable monitoring of neonatal physiological parameters in clinical settings, especially for neonatal cases with unstable blood circulation or low perfusion.